Fluorescent penetrant inspection (FPI) reveals surface-breaking cracks, porosity, laps and seams that are too fine to see with the unaided eye. A fluorescent dye is drawn into open discontinuities, the excess is removed, a developer draws the dye back out, and indications glow under UV-A light. CCWI performs FPI on castings, forgings, machined parts and welds in metals such as nickel, cobalt, titanium, aluminum and steel.
ASTM E1417/E1417M classifies penetrant systems by type, method and sensitivity. The drawing or customer specification sets which system is required.
| Classification | Options |
|---|---|
| Type | Type I fluorescent dye; Type II visible dye |
| Method | A water washable; B post-emulsifiable, lipophilic; C solvent-removable; D post-emulsifiable, hydrophilic |
| Sensitivity (Type I) | Level ½ very low, 1 low, 2 medium, 3 high, 4 ultrahigh |
| Developer form | a dry powder; b water-soluble; c water-suspendable; d nonaqueous for Type I; e nonaqueous for Type II; f specific application |
| Document | Use |
|---|---|
| ASTM E1417/E1417M | Liquid penetrant testing practice |
| SAE AMS 2644 | Qualification of penetrant inspection materials |
| AWS D17.1/D17.1M | Aerospace fusion weld inspection and acceptance |
| OEM and customer specifications | Part-specific process and acceptance criteria |
FPI finds surface-breaking discontinuities such as cracks, porosity, laps, seams and cold shuts in castings, forgings, machined parts and welds. It works on nonporous metals, including aluminum and titanium.
Type I fluorescent penetrant glows under UV-A light in a darkened area and is graded by sensitivity level. Type II visible (red) dye is viewed in white light and is not assigned a sensitivity level. Fluorescent penetrant is normally required for aerospace parts.
The drawing, customer specification or OEM process sets the sensitivity level. For example, ASTM E1417 requires Type I, Method C or D, sensitivity Level 3 or 4 for maintenance or overhaul inspection of turbine engine critical components.
No. Penetrant testing only finds discontinuities open to the surface. Internal porosity, shrinkage and inclusions in castings are found with radiography (film, CR or DR).